Select a stepper motor together with its load profile, driver and transmission. Holding torque, running torque, command resolution and measured positioning accuracy describe different things.
Separate holding torque from running torque
Holding torque describes an energized motor at standstill; it is not the torque available at operating speed. Compare torque-speed curves under the intended supply, phase current and drive settings, including the torque needed to accelerate the load inertia.
Resolution is not positioning accuracy
An open-loop drive commands motion through pulses, but the pulse count does not prove that the shaft reached its target. Overload, excessive acceleration and resonance can cause missed steps. Evaluate feedback and fault detection where position must be confirmed. Microstepping improves command resolution but does not remove backlash, compliance or assembly error.
Start with the application and an identified model
The current catalogue lists printer and stage-lighting applications for PST.39HB, automation equipment for PST.57HB, and valve switching for PST.24BY1903-001. Start by comparing the dimensional and electrical information for the identified configuration.
Record the sample-test conditions
- Load torque, inertia, target speed and acceleration time
- Supply voltage, driver phase current and microstep setting
- Mounting envelope, shaft, transmission ratio and backlash
- Duty cycle, holding requirement, temperature rise and noise
- Repeat-positioning measurements and missed-step detection in the assembly